The engineered steel kit. A complete structure.
Every member is welded, primed and cut to length off site. On site it bolts together — no cutting, no welding. The same portal-frame concept scales from a small studio to a wide-span home simply by stepping up the steel.
- Structural steel
- AISC 360
- Wind basis
- 112 mph design speed
- Scope
- Footings to a complete structure
Off-site fabrication, engineered to code.
Welded and primed in the factory, engineered to AISC 360, AISI S100 and ASCE 7. Three size tiers cover the full span range, and the scope runs from footings to a complete structure, including internal wall framing, windows, doors and cladding.
Off-site fabrication
Every frame member welded, primed and cut to length in the factory before it reaches site.
Engineered to code
AISC 360 hot-rolled steel, AISI S100 cold-formed steel, ASCE 7 structural and wind loads, IRC residential provisions.
Three size tiers
Perimeter channel size steps up with module width — see the tier table below.
Scope
Footings through to a complete structure, including internal wall framing, windows, doors and cladding.
Standing-seam cladding
Concealed-fix vertical standing-seam profile, 10 7/16 in cover, one system for both roof and wall.
Base system and primary structure.
| Component | Spec |
|---|---|
| External perimeter | 7 / 8 / 9 in channel (ASTM A36), sized to module width |
| Base subframe | Cold-formed steel box section, 6 × 2 in × 14 gauge |
| Post-to-base detail | 3 × 7 in × 1/2 in baseplate, 3/8 in stiffener, 4× 3/4 in anchor bolts |
| Portal frames | 6 or 7 in channel (span-dependent), 35° gable, ASTM A36 |
| Eave beams | 5 in channel, continuous |
| Apex connection | 3 × 7 in × 3/8 in plate, 3/4 in bolts |
| Purlin / eave connection | 3/8 in plate, 2× 5/8 in bolts |
| Welds | 1/4 in fillet, AWS D1.1 |
| Shop finish | Primed; hot-dip galvanizing optional to ASTM A123 |
| Roof purlins | 6 in cold-formed C-section @ 19 3/16 in centers |
| Wall framing | Cold-formed 2 × 4 in studs @ 23 5/8 in o.c., double stud at openings |
| Roof & wall cladding | Standing seam, 10 7/16 in vertical cover |
| Structural bolts | ASTM F3125 Grade A325, 1/2 in min |
Footings to a complete structure.
Every kit goes up in the same order — footings, portal frame, purlins and bracing, then the Enseam cladding. Portals always land at 13′-1½″ max centers.
01 / 12
Footings and base beams
The footings are set, then the 8 in channel base beams are bolted down to form the perimeter the whole frame is set out from.
Step 1 of 12
Sequence shown is diagrammatic, single bay at 13′-1½″ portal spacing. From the Structural Kit System supply specification.
Same concept, bigger steel.
The portal frame concept is identical across every tier — only the perimeter and portal channel sizes step up with module width.
| Tier | Module width | Perimeter channel | Portal channel |
|---|---|---|---|
| T1 · Standard | Up to 9′-10″ | 7 in | 6 in |
| T2 · Mid | 9′-10″ – 11′-6″ | 8 in | 6 or 7 in |
| T3 · Wide | 11′-6″ – 14′-9″ | 9 in | 7 in |
Beyond the documented tiers, the kit is also supplied as a 16′-5″ or 19′-8″ clear open span on 12 in channel portals, in lengths from 31′-2″ to 50′-10″. These widths are kit supply only — a finished building wider than 14′-9″ cannot be moved on a road — and the internal layout is drawn with you rather than selected from a plan set, because nothing inside the perimeter is load bearing.
Sourced from the Structural Kit System supply specification, June 2026. The 16′-5″ and 19′-8″ open-span widths sit outside that document and are current Arc supply direction. Module length is variable up to an 26′-3″ standard bay, extended by combining bays; multi-module layouts run side-by-side via a shared central portal or independent frames. Figures presented here are specific to the Kit System supply spec and are separate from the channel width bands quoted on the main Proof section of this site.
Built to code, not to guesswork.
| Structural steel | AISC 360 |
| Cold-formed steel | AISI S100 |
| Structural loads | ASCE 7 |
| Wind loads | ASCE 7 — 112 mph basic design wind speed |
| Residential live load | 40 psf floors / 20 psf roof |
| Roof dead load | 3 psf minimum |
| Welding | AWS D1.1 — 1/4 in continuous fillet |
| Bolting | AISC 360 + ASTM F3125 Grade A325, 1/2 in min |
| Galvanizing | ASTM A123, where specified |
Member sizes and geometry are the Arc Structural Kit System supply specification, June 2026, relabelled in imperial — the building is physically identical to the Australian system. US code references are the equivalent standards for the same design intent; the governing wind, snow and seismic loads for your site and the stamped calculations are confirmed by the licensed engineer of record in Tennessee before fabrication. Portal spacing is always at 13′-1½″ max.
Included. Not included.
Included
- + Channel perimeter base frame
- + Cold-formed steel floor subframe
- + Portal frames with welded cleats
- + 5 in channel eave beams
- + C15019 Cee purlins
- + Cold-formed wall framing
- + 10 7/16 in Enseam roof and wall cladding
- + Aluminum windows and doors
- + All structural connections and hardware
- + Shop prime coat
- + Fabrication drawings (IFC set)
- + Internal fit-out, supplied through Arc Elements
Not included
- - Concrete pier or footing construction
- - Internal linings and insulation
- - Electrical and plumbing rough-in
- - Crane and erection labor
- - Building permit documentation
- - Site preparation and access
Structural Kit System supply specification, June 2026, page 5.
Need documentation and approval before the kit ships? Start with Arc Studio, or fit it out with Arc Elements once it's up.
Price a kit